DH-1223 Load control request for single control
Event description
The load control service provider submits a request for single load control at the accounting point.
In the request, the service provider specifies whether the load control relay should be set to the closed or open state.
See additional information about load control requests for single control here.
Parties
Load control service provider
Datahub
DSO
Time limits
Submitting a load control request |
|---|
There are no time limits for submitting a single load control request. |
Event processing in Datahub
Step | Description |
Processing of the load control request | No processing is performed in Datahub based on the content of the load control request. |
Information storage
Origin of information | Information stored |
Information reported by the party | The information contained in the load control request is not stored in Datahub. |
Return of information
Party | Description | Message |
|---|---|---|
Load control service provider | Notification of a forwarded or rejected request. |
Forwarding of information
Party | Description | Message |
|---|---|---|
DSO | An accepted load control request is forwarded to the DSO for execution. |
Event cancellation
The request cannot be cancelled. If necessary, a new corrected request must be submitted once the previous request for the same accounting point has been confirmed.
Validation rules
Please see Datahub Validation Rules for a more thorough list.
Rule | Error code | Note |
|---|---|---|
The accounting point must be found in Datahub and be valid at the time the event is processed. | EC.MPT.115 |
|
The accounting point must have status “connected”. | EC.LCR.100 |
|
The load control service provider must have a valid load control authorisation for the accounting point. | EC.LCR.101 |
|
If the message specifies relay 1 as the controlled relay, the accounting point’s load‑controllability information must be either “Relay 1 controllable” or “Relay 1 or relay 2 controllable”. | EC.LCR.102 |
|
If the message specifies relay 2 as the controlled relay, the accounting point’s load‑controllability information must be either “Relay 2 controllable” or “Relay 1 or relay 2 controllable”. | EC.LCR.102 |
|
The reported party identification must match the sender of the control request. | EC.AGR.115 |
|
Please observe that the list is not complete. | ||