E58 Structural data, accounting point

E58 Structural data, accounting point

Message name: MasterDataMPEvent

Information field

T

P

Format

Example

XML element

Note

Information field

T

P

Format

Example

XML element

Note

Payload

1

1..1

 

 

Transaction

 

Start of occurrence

2

1..1

Time stamp

2015-06-12T21:00:00+00:00

StartOfOccurrence

 

Original message identification

2

0..1

A36

123e4567-e89b-12d3-a456-426656756520

OriginalBusinessDocumentReference

 

Original message sender

2

0..1

A13

6458237348480

OriginalBusinessDocumentSender

schemeAgencyIdentifier=9

Update reason

2

0..1

A4

BM02=Estimated annual consumption update

UpdateReason

listAgencyIdentifier=NFI

Only used when DSO updates estimated annual consumption.

Description

2

0..1

A150

Free-form description

Description

 

Basic accounting point data

2

1..1

 

 

MeteringPointUsedDomainLocation

 

Accounting point identification

3

1..1

A90

645823734848458216

Identification

schemeAgencyIdentifier=9

Accounting point status

3

0..1

A4

  • AE01=Connected

  • AE02=Disconnected

  • AE03=Under construction

  • AE04=Removed from use

  • AE05=Deleted

PhysicalStatusType

listAgencyIdentifier=NFI

Accounting point type

3

0..1

A4

  • AG01=Consumption

  • AG02=Production

MeteringPointType

listAgencyIdentifier=NFI

Accounting point sub-type

3

0..1

A4

  • AQ01=Normal

  • AQ02=Building accounting point

  • AQ03=Production unit’s own consumption

  • AQ04=Virtual

MeteringPointSubType

listAgencyIdentifier=NFI

Remotely connectable

3

0..1

A1

  • 0=Not remotely connectable

  • 1=Remotely connectable

RemoteConnectable

 

Time division

3

0..1

A1

  • 1=One rate metering

  • 2=Two rate metering night/day

  • 3=Two rate metering winter day/other

MeteringTimeDivision

 

Meter number

3

0..1

A50

12345

MeterIdentification

 

Load controllable

3

0..1

A4

  • BS01 = Not controllable

  • BS02 = Relay 1 controllable

  • BS03 = Relay 2 controllable

  • BS04 = Relay 1 or 2 controllable

LoadControllable

 

Related accounting point identification

3

0..1

A90

645823734848458216

RelatedMeteringPoint

schemeAgencyIdentifier=9

Community Identification

3

0..1

A50

6430076050014123456

CommunityIdentification

 

Community Name

3

0..1

A200

EnergyTogether

CommunityName

 

Is netting applied

3

0..1

A1

  • 0=Netting not applied

  • 1=Netting applied

Netting

 

Area information

3

1..1

 

 

MeteringGridAreaUsedDomainLocation

 

Metering grid area identification

4

1..1

A50

44Y1001A1001A46L

Identification

schemeAgencyIdentifier=305

Accounting point address

3

0..8

 

 

MeteringPointAddress

 

Address type

4

1..1

A4

  • AF01=Main address

  • AF02=Additional address

Type

listAgencyIdentifier=NFI

Street name

4

0..1

A90

Syyriankatu

StreetName

 

Building number

4

0..1

A10

21

BuildingNumber

 

Stairwell identification

4

0..1

A10

A

FloorIdentification

 

Apartment

4

0..1

A10

13

RoomIdentification

 

Postal code

4

0..1

A10

00510

Postcode

 

Post office

4

0..1

A50

HELSINKI

CityName

 

Country

4

0..1

A2

  • AX

  • FI

  • NO

  • RU

  • SE

CountryCode

schemeAgencyIdentifier=5

ISO 3166 alpha-2

Address specifier

4

0..1

A150

Third from the left when looking from the bridge

AddressFreeForm

 

Language

4

0..1

A2

  • fi

  • sv

Language

schemeAgencyIdentifier=5

Coordinates

3

0..1

 

 

MPPositionMeteringPointGeographicalCoordinate

 

Latitude

4

1..1

A10

61°10,27'N

Latitude

 

Longitude

4

1..1

A10

24°33,67'E

Longitude

 

Accounting point characteristics

3

0..1

 

 

MPDetailMeteringPointCharacteristic

 

Remotely readable

4

0..1

A1

  • 1=Remotely readable

  • 0=Not remotely readable

RemoteReadable

 

Metering method

4

0..1

A3

  • E13=Continuous metering

  • E14=Reading metering

  • E16=Unmetered

MeteringMethod

 

Metering time step

4

0..1

A25

  • PT15M

  • PT1H

ResolutionDuration

Format: PnYnMnDTnHnMnS

User group

4

0..1