F35 Load control message

F35 Load control message

Message name: AuthorisationRequestEvent

Information field

T

P

Format

Example

XML element

Note

Information field

T

P

Format

Example

XML element

Note

Payload

1

1..1

 

 

Transaction

 

Party identification

2

1..1

A13

6458237348480

PartyIdentification

schemeAgencyIdentifier=9

Identification of the party that made the control request.

Basic accounting point data

2

1..1

 

 

MeteringPointUsedDomainLocation

 

Accounting point identification

3

1..1

A90

645823734848458216

Identification

schemeAgencyIdentifier=9

End device control request

2

1..1

 

 

EndDeviceControl

 

Request identification

3

1..1

A36

 

Identification

 

Relay identification

3

0..1

A1

1

2

RelayIdentification

 

Time stamp

3

0..1

Time stamp

2025-12-02T15:45:15+00:00

ExecutionTimeStamp

Only used in the confirmation event

Description

3

0..1

A150

 

Description

 

Request type

3

1..1

 

 

EndDeviceControlType

 

Type

4

1..1

A4

  • BO01=Single control

  • BO02=Scheduled control

  • BO03=Scheduled control correction

  • BO04=Calendar control

  • BO05=Confirmation

Type

 

Confirmation of control

4

0..1

A4

  • BR01=Control OK

  • BR02=Control not OK

SubType

Only used in the confirmation event

Control period

3

0..7

 

 

DeviceTiming

Details of the control request for scheduled control

Relay state

4

1..1

A4

  • BP01=Relay closed

  • BP02=Relay open

Request

 

Start time

4

0..1

Time stamp

2025-12-02T22:00:00+00:00

Start

Timestamp including time zone

End time

4

0..1

Time stamp

2025-12-03T04:30:00+00:00

End

Timestamp including time zone

Day of the calendar control

3

0..7

 

 

CalendarDay

Details of the control request for calendar control

Day of the week

4

1..1

A4

  • BQ01=Monday

  • BQ02=Tuesday

  • BQ03=Wednesday

  • BQ04=Thursday

  • BQ05=Friday

  • BQ06=Saturday

  • BQ07=Sunday

DayOfWeek

 

Control period

4

1..7

 

 

Period

 

Relay state

5

1..1

A4

  • BP01=Relay closed

  • BP02=Relay open

Request

 

Start time

5

1..1

A5

00:45

StartTime

Time in Finnish time without time zone.

The start time of the first control period of the day must be 00:00.

End time

5

1..1

A5

07:00

EndTime

Time in Finnish time without time zone.

The end time of the last control period of the day must be 24:00.

Control request details

3

0..1

 

 

ControlDetails

Details of the control request for single control

Relay state

4

1..1

A4

  • BP01=Relay closed

  • BP02=Relay open

Request