F08 Metering data request

F08 Metering data request

Message name: RequestMeasuredDataInfo

Information field

T

P

Format

Example

XML element

Note

Information field

T

P

Format

Example

XML element

Note

Payload

1

1..1

 

 

Transaction

 

Request period

2

1..1

 

 

RequestPeriod

 

Start time

3

1..1

Time stamp

2015-06-12T21:00:00+00:00

Start

 

End time

3

1..1

Time stamp

2015-06-12T21:00:00+00:00

End

 

Time step

2

0..1

A25

  • PT15M

  • PT1H

  • P1D

  • P1M

  • P1Y

ResolutionDuration

Format: PnYnMnDTnHnMnS

Invoice relevant

2

0..1

A1

0=Not invoice relevant

1=Is invoice relevant

InvoiceRelevant

The ”Invoice relevant” element must be used together with the ”Metering point type” element with value ”F01”.

Metering point

2

1..1

 

 

MeteringPoint

 

Metering point type

3

0..n

A4

F01=Accounting point

E18=Production

E20=Connection point

MeteringPointType

listAgencyIdentifier=NFI

Accounting point type

3

0..n

A4

AG01=Consumption

AG02=Production

AccountingPointType

listAgencyIdentifier=NFI

Metering point identification

3

0..n

A90

707057500022939815

Identification

schemeAgencyIdentifier=9

Metering point identification may be:

  • accounting point ID or small-scale production accounting point ID

  • exchange point ID

  • production unit ID

Metering grid area identification

3

0..n

A50

44Y1001A1001A46L

MeteringArea

schemeAgencyIdentifier=305

Product

2

0..n

 

 

Product

 

Product identification

3

1..1

A50

8716867000030=Active energy

8716867000047=Reactive energy

ProductIdentification

 

Unit type

3

1..1

A6

  • kWh

  • MWh

  • kvarh

  • Mvarh

UnitType

 

Response event: A metering data event is used as a response event.