E66 Metering data

E66 Metering data

Message name: EnergyTimeSeries

Information field

T

P

Format

Example

XML element

Note

Information field

T

P

Format

Example

XML element

Note

Payload

1

1..n

 

 

Transaction

 

Unique transaction ID

2

1..1

A36

 

UniqueIdentification

Timeseries UUID identification

Metering time series identification

2

0..1

A90

FI_HKE001_12345

Identification

Time series ID used by the metering responsible party. Datahub does not set a naming rule for the ID.

Invoice relevant

2

0..1

A1

0=Not invoice relevant

1=Is invoice relevant

InvoiceRelevant

 

Reporting period

2

1..1

 

 

ObservationPeriodTimeSeriesPeriod

 

Time step

3

0..1

A25

  • PT15M

  • PT1H

  • P1D

  • P1M

  • P1Y

ResolutionDuration

Format: PnYnMnDTnHnMnS

Start time

3

1..1

Time stamp

2015-06-12T21:00:00+00:00

Start

 

End time

3

1..1

Time stamp

2015-06-12T21:00:00+00:00

End

 

Metering type

2

1..1

 

 

ProductIncludedProductCharacteristic

 

Metering time series type

3

1..1

A18

8716867000030=Active energy

8716867000139=Reactive energy, input

8716867000146=Reactive energy, output

8716867000047=Reactive energy (Connection points)

Identification

 

Unit

3

1..1

A6

  • Wh

  • kWh

  • MWh

  • GWh

  • varh

  • kvarh

  • Mvarh

  • Gvarh

UnitType

 

Metering characteristics

2

1..1

 

 

MPDetailMeasurementMeteringPointCharacteristic

 

Metering point type

3

1..1

A3

F01=Accounting Point

E18=Production

E20=Connection point

MeteringPointType

 

Metering point

2

1..1

 

 

MeteringPointUsedDomainLocation

 

Metering point identification

3

1..1

A90

707057500022939815

Identification

 

schemeAgencyIdentifier=9

Area information

2

0..1

 

 

MeteringGridAreaUsedDomainLocation

 

Metering grid area identification

3

1..1

A90

44Y1001A1001A46L

Identification

schemeAgencyIdentifier=305

Input area

2

0..1

 

 

InAreaUsedDomainLocation

 

Metering grid area identification

3

1..1

A90

44Y1001A1001A46L

Identification

schemeAgencyIdentifier=305

Output area

2

0..1

 

 

OutAreaUsedDomainLocation

 

Metering grid area identification

3

1..1

A90

44Y1001A1001A46L

Identification

schemeAgencyIdentifier=305

Time series values

2

1..n

 

 

OBS

 

Position

3

1..1

I4

1

SEQ

Position specifies time step order number in relation to start time. For example, the first hour of the time period receives the value 1, the second value 2, etc.

Values

3

1..1

 

 

EOBS

 

<choice 1>

Value

4

1..1

D8.6

1.123

QTY

In message E66, a schema choice element <xsd:choice> is used. Submit either fields Value and Status or field Value missing, but not both.

Status

4

0..1

A3

Z02=Uncertain

99=Estimated

Z01=Corrected OK

Z04=Partially missing

21=Temporary

56=Estimated, approved for billing

QQ

</choice 1>

<choice 2>

Value missing

4

1..1

A1

1=true

QM

In message E66, a schema choice element <xsd:choice> is used. Submit either fields Value and Status or field Value missing, but not both.

</choice 2>