DH-211 Metering data reporting
Message DH-211 (reporting data) is of message type E66.
Message payload includes the following information:
Information field | Level | Necessity | Field content | Note |
|---|---|---|---|---|
Payload | 1 | 1..n |
|
|
Unique transaction ID | 2 | 1..1 |
| As the metering time series, identification of the reporting system is not always unique, and unique UUID is needed. The identification is used with the acknowledgement message. |
Metering time series identification | 2 | 0..1 |
| Time series data is linked to the metering point based on metering point identification. Metering time series identification is the identification used by the reporting system and it can be used for handling possible error situations. |
Reporting period | 2 | 1..1 |
|
|
Time step | 3 | 1..1 |
|
|
Start time | 3 | 1..1 |
|
|
End time | 3 | 1..1 | End time of the last interval reported, not the start time of the last interval. |
|
Metering type | 2 | 1..1 |
|
|
Metering time series type | 3 | 1..1 |
| For connection points reactive energy is reported in the same way as active energy, using output and input areas. For other metering points metering time series type reactive energy output and input is used for reporting. |
Unit | 3 | 1..1 |
|
|
Metering characteristics | 2 | 1..1 |
|
|
Metering point type | 3 | 1..1 |
|
|
Metering point | 2 | 1..1 |
|
|
Metering point identification | 3 | 1..1 |
|
|
Area information | 2 | 0..1 |
| Not used for exchange point metering. |
Metering grid area identification | 3 | 1..1 |
|
|
Output area | 2 | 0..1 |
| Only used for exchange point metering. |
Output area identification | 3 | 1..1 |
|
|
Input area | 2 | 0..1 |
| Only used for exchange point metering. |
Input area identification | 3 | 1..1 |
|
|
Time series values | 2 | 1..n |
|
|
Position | 3 | 1..1 |
| In an event, a complete timeline with time series values for the whole reporting period must always be delivered. For each position, either value or value missing data is presented for the reporting period. |
Values | 3 | 1..1 |
| Either a value or an 'value missing' indicator must be provided. All values must always be positive. For exchange points, both directions of transfer must be reported separately. |
<choice 1> | ||||
Value | 4 | 1..1 |
|
|
Status | 4 | 0..1 |
| Status is presented if other than metered. (136=OK) (Missing) is not presented, only expressed as ‘value missing’ in the field. Uncertain Estimated Corrected OK |
</choice 1> | ||||
<choice 2> | ||||
Value missing | 4 | 1..1 |
|
|
</choice 2> | ||||