DH-211 Reporting metering data

DH-211 Reporting metering data

image-20251014-111251.png
Reporting metering data

Event description

A party responsible for metering (the DSO) reports the metering data for a metering point (accounting point, exchange point or production unit) to Datahub.

Parties

  • DSO

  • Datahub

  • Supplier

  • Third party

Time limits

Reporting metering data

Reporting metering data

Time limits (time limits for reporting metering data, status processing and monitoring of metering data reports) must be observed, but corrections are permitted throughout the storage period for the metering data.

Event processing in Datahub

Step

Description

Metering point information on reactive power series availability

Datahub updates the value of the ‘reactive energy time series available’ accounting point attribute to ‘yes’ if reactive energy is reported for the accounting point and the attribute has the value ‘no’.

Netting calculation

Datahub performs the netting calculation based on the metering data reported by the distribution system operator, provided that all metering data required for the calculation has been submitted to Datahub. The results of the calculation are forwarded to the parties entitled to the data.

Energy community calculation

Datahub performs the energy community calculation based on the metering data reported by the distribution system operator, provided that all metering data required for the calculation has been submitted to Datahub. The results of the calculation are forwarded to the parties entitled to the data.

Information storage

Origin of information

Information stored

Information reported by the party

The metering data for the metering points and the the time period from which the data originates.

Information processed by Datahub

Accounting point information on the availability of reactive power series.

Return of information

Party

Description

Message

Party

Description

Message

DSO

Positive or negative acknowledgement for each transaction. Datahub rejects the message content on a per time series basis. This means that the entire message is not rejected due to a single error; only the time series containing errors are rejected.

ACK

Forwarding of information

Party

Description

Note

Message

Party

Description

Note

Message

Supplier

Metering data that Datahub receives and accepts is forwarded to the suppliers that have the rights to the information. Corrected time series data for a supplier’s agreement period will not be forwarded to the supplier if the supplier’s agreement has ended more than six weeks before the data reporting date.

The forwarded message contains two timestamps, when metering data is received in Datahub and when metering data is updated to database in Datahub. Metering data is forwarded using the unit with which the DSO has reported the metering data to Datahub.

If the DSO reports the metering data for a time interval within which the invoice relevant information changes, Datahub splits the forward message into two transactions covering the periods before and after the time of the change.

DH-211

Third party

Metering data that Datahub receives and accepts is forwarded to third parties that have the rights to the information.

DSO

Metering data for exchange points is forwarded to the DSO of the exchange point’s other metering grid area, if it is another party than the party reporting the data.

Significant errors and consequences

Possible metering errors and subsequent balance errors are processed in accordance with sections Correction of metering data and Management of balance deviation.

Event cancellation

Metering data is corrected by means of a new notification event.

Validation rules

Please see Datahub Validation Rules for a more thorough list.

Rule

Error code

Note

Rule

Error code

Note

A single notification event may contain a maximum of 10,000 metering time series and each metering time series may contain a maximum of 10,000 time-step values.

EC-MDM-PMV-001/
EC-MDM-PMV-002

 

The metering point is recorded in the system.

EC-MDM-PTV-005

 

The party (distribution system operator or third party) is entitled to provide metering data to the metering grid area.

EC-MDM-PTV-021

 

The metering data resolution is the same as the time step reported for the metering point.

EC-MDM-VAL-INTERVAL

 

The notified period is not in the future or more than 6 years in the past.

EC-MDM-PTV-018

 

The time series contains a value (or ‘Value absent’ information) for each position in the reporting period.

EC-MDM-PMV-003

 

The metering point is not in the ‘Under construction’ status.

EC-MDM-PTV-006

 

The transaction cannot consist of unchanged metering data (status and value) alone.

EC-MDM-VAL-DUPTRANS

 

Metering data cannot be replaced with a weaker status.

EC-MDM-VAL-QUAL

 

The value cannot be negative.

EC-MDM-VAL-RANGE

 

Metering point-specific validation of measurements (not all of these rules are yet included in this table).

 

 

 

 

 

Please observe that the list is not complete.