Descriptions of imbalance settlement calculations
- 1 Supplier’s metered sum delivery
- 2 Supplier’s profiled sum delivery
- 3 Supplier’s small-scale production by production type
- 4 Supplier’s metered PU’s own consumption sum
- 5 Supplier’s profiled PU’s own consumption sum
- 6 MGA exchange sum
- 7 Metering grid area losses
- 8 Metering grid area’s metered sum delivery
- 9 Metering grid area’s profiled sum delivery
- 10 Metering grid area’s small-scale production by production type
- 11 Metering grid area’s metered PU’s own consumption sum
- 12 Metering grid area’s profiled PU’s own consumption sum
- 13 Metering grid area’s production unit sum by production type
- 14 Metering grid area’s exchange sum total
- 15 Metering grid area’s small-scale production sum total
- 16 Metering grid area’s production unit total
This page describes in more detail how time series are selected for imbalance settlement calculations. In the descriptions of calculations, input refers to data needed to calculate an individual imbalance settlement calculation. Other selection criteria refers to criteria that are based on which of the time series is selected as the basis for the calculations. Fulfillment of these criteria is verified by time-step. Only time-steps from the selected time series for which all the criteria are met are included in the calculated sum. In calculations based on accounting point information, especially the metering method may change by time-step. In practice, the accounting point type cannot change and the metering grid area to which the accounting point belongs changes very rarely.
Supplier’s metered sum delivery
Description:
Supplier and metering grid area specifically calculated sum, in accordance with the official imbalance settlement period, of the metering time series of continuously metered accounting points.
Datahub’s balance settlement type code: BI02
Input:
Supplier
Metering grid area
Other selection criteria for metering time series:
The supplier in the input has valid balance information to the accounting point at the time-step of calculation
Accounting point belongs to the metering grid area in the input
Accounting point type = Consumption
Accounting point’s metering time series type = Active energy
Accounting point metering method = Continuous metering
Supplier’s profiled sum delivery
Description:
Supplier and metering grid area specifically calculated sum, in accordance with the official imbalance settlement period, of the metering time series of profiled, i.e., not continuously metered, accounting points.
Datahub’s balance settlement type code: BI01
Input:
Supplier
Metering grid area
Other selection criteria for metering time series:
The supplier in the input has valid balance information to the accounting point at the time-step of calculation
Accounting point belongs to the metering grid area in the input
Accounting point type = Consumption
Accounting point’s metering time series type = Active energy
Accounting point metering method = Reading metering or Unmetered
Supplier’s small-scale production by production type
Description:
Supplier, metering grid area and (NBS) production type specifically calculated sum, in accordance with the official imbalance settlement period, of accounting points’ metering time series of the production type.
Datahub’s balance settlement type code: BI05
Input:
Supplier
Metering grid area
(NBS) production type
Other selection criteria for metering time series:
The supplier in the input has valid balance information to the accounting point at the time-step of calculation
Accounting point belongs to the metering grid area in the input
Accounting point type = Production
Accounting point’s metering time series type = Active energy
Accounting point metering method = Continuous metering
Supplier’s metered PU’s own consumption sum
Description:
Supplier and metering grid area specifically calculated sum, in accordance with the official imbalance settlement period, of the metering time series of continuously metered own consumption accounting points.
Datahub’s balance settlement type code: BI04
Input:
Supplier
Metering grid area
Other selection criteria for metering time series:
The supplier in the input has valid balance information to the accounting point at the time-step of calculation
Accounting point belongs to the metering grid area in the input
Accounting point sub-type = Own consumption
Accounting point’s metering time series type = Active energy
Accounting point metering method = Continuous metering
Supplier’s profiled PU’s own consumption sum
Description:
Supplier and metering grid area specifically calculated sum, in accordance with the official imbalance settlement period, of the metering time series of profiled, i.e. other than continuously metered, own consumption accounting points.
Datahub’s balance settlement type code: BI03
Input:
Supplier
Metering grid area
Other selection criteria for metering time series:
The supplier in the input has valid balance information to the accounting point at the time-step of calculation
Accounting point belongs to the metering grid area in the input
Accounting point sub-type = Own consumption
Accounting point’s metering time series type = Active energy
Accounting point metering method = Reading metering or Unmetered
MGA exchange sum
Description:
Exchange point sum refers to the total electricity transmission between two metering grid areas that is calculated from the metering time series of the exchange points between the two metering grid areas in question. Exchange point sum includes information about which metering grid area is the ‘In Area’ (the area electricity is transmitted to) and which is the ‘Out Area’ (the area electricity is transmitted from).
Exchange point sums are calculated between all two metering grid areas, which have at least one exchange point metering.
Datahub’s balance settlement type code: BI18
Input:
Out Area
In Area
Other selection criteria for metering time series to be added:
Metering point type = Exchange point
Metering grid area losses
Description:
Transmission losses of the metering grid area in accordance with the official imbalance settlement period.
Metering grid area losses are calculated based on other calculated sums of the metering grid area using formula:
Metering grid area losses = Connection point sums − metered sum deliveries − profiled sum deliveries − metered own consumption sums − profiled own consumption sums + small scale production sums + production unit productions
Datahub’s balance settlement type code: BI07 and BI08
Metering grid area’s metered sum delivery
Description:
Total sum of metered sum deliveries of the suppliers in the metering grid area.
Datahub’s balance settlement type code: BI11
Input:
Metering grid area
Other selection criteria for times series to be added:
Suppliers’ metered sum deliveries for the metering grid area in the input.
Metering grid area’s profiled sum delivery
Description:
Total sum of profiled sum deliveries of the suppliers in the metering grid area.
Datahub’s balance settlement type code: BI10
Input:
Metering grid area
Other selection criteria for times series to be added:
Suppliers’ profiled sum deliveries for the metering grid area in the input.
Metering grid area’s small-scale production by production type
Description:
Total sum of metering grid area’s suppliers’ small-scale production sums per production type.
Datahub’s balance settlement type code: BI14
Information to be calculated:
Total sum of metering grid area’s suppliers’ small-scale production sums
Input:
Metering grid area
(NBS) Production type
Other selection criteria for the time series to be added:
Suppliers’ (production type specific) small-scale productions for the metering grid area and production type in the input.
Metering grid area’s metered PU’s own consumption sum
Description:
Total sum of the metering grid area’s suppliers’ metered own consumption sums.
Datahub’s balance settlement type code: BI13
Input:
Metering grid area
Other selection criteria for the time series to be added:
Suppliers’ metered own consumption sums for the metering grid area in the input.
Metering grid area’s profiled PU’s own consumption sum
Description:
Total sum of the metering grid area’s suppliers’ profiled own consumption sums.
Datahub’s balance settlement type code: BI12
Input:
Metering grid area
Other selection criteria for the time series to be added:
Suppliers’ profiled own consumption sums for the metering grid area in the input.
Metering grid area’s production unit sum by production type
Description:
Total production of metering grid area’s production units per production type.
Datahub’s balance settlement type code: BI16
Input:
Metering grid area
(NBS) Production type
Other selection criteria for the time series to be added:
Production units’ time series with the input production type for the metering grid area in the input
Metering grid area’s exchange sum total
Description:
Metering grid area’s total exchange point sum is the remainder of electric energy input to the grid and output from the grid. Total exchange point sum is calculated by adding together, including sign, all exchange point sums where the metering grid area in question is either the In Area or Out Area.
Datahub’s balance settlement type code: BI19
Input:
Metering grid area
Other selection criteria for the time series to be added:
Exchange point sums, where the input metering grid area is either ‘In Area’ or ‘Out Area’.
Metering grid area’s small-scale production sum total
Description:
Total production of metering grid area’s small-scale productions.
Datahub’s balance settlement type code: BI15
Input:
Metering grid area
Other selection criteria for the time series to be added:
Input metering grid area’s (production type specific) small-scale production sums
Metering grid area’s production unit total
Description:
Total production of metering grid area’s production units.
Datahub’s balance settlement type code: BI17
Input:
Metering grid area
Other selection criteria for the time series to be added:
Input metering grid area’s (production type specific) production unit sums