DH-122-2 Forwarding accounting point information to supplier

DH-122-2 Forwarding accounting point information to supplier

image-20251001-113206.png
Information to be forwarded to supplier during an accounting point update

Message DH-122-2 is of message type E58.

Message payload includes the following information:

Information field

Level

Necessity

Field content

Note

Payload

1

1..1

 

 

Start of occurrence

2

1..1

 

 

Original message identification

2

0..1

The field contains the message identifier DH-122-1, DH-126-1, DH-127-1, DH-141, or DH-142, depending on the original event.

Field usage

Original message sender

2

0..1

The field contains the message identifier DH-122-1, DH-126-1, DH-127-1, DH-141, or DH-142, depending on the original event.

Field usage

Description

2

0..1

Optional reason for update or rejecting an update request.

 

Basic accounting point data

2

1..1

 

 

Accounting point identification

3

1..1

 

 

Accounting point status

3

1..1

  • Connected

  • Disconnected

  • Under construction

 

Accounting point type

3

1..1

  • Consumption

  • Production

 

Accounting point sub-type

3

1..1

  • Normal

  • Building accounting point

  • Production unit’s own consumption

  • Virtual

 

Remotely connectable

3

1..1

Yes/No

 

Time division

3

1..1

  • One rate metering

  • Two rate metering night/day

  • Two rate metering winter day/other

 

Meter number

3

0..1

Active metering meter number

 

Related accounting point identification

3

0..1

Identifier of the corresponding consumption or production accounting point related to the small-scale production site.

Related accounting point data is maintained using events DH-126 and DH-127. This information is not updated as part of the DH-122 event, but any existing data is also forwarded in connection with the DH-122 event.

Energy community identification

3

0..1

 

Energy community data is maintained using DH-14x events. This information is not updated as part of the DH-122 event, but any existing data is also forwarded in connection with the DH-122 event.

Energy community name

3

0..1

 

Energy community data is maintained using DH-14x events. This information is not updated as part of the DH-122 event, but any existing data is also forwarded in connection with the DH-122 event.

Is netting applied

3

0..1

0=Netting not applied
1=Netting applied

 

Area information

3

1..1

 

 

Metering grid area identification

4

1..1

EIC code is used.

 

Accounting point addresses

3

1..8

 

 

Address type

4

1..1

  • Main address

  • Additional address

 

Street name

4

1..1

 

 

Building number

4

0..1

 

 

Stairwell identification

4

0..1

 

 

Apartment

4

0..1

 

 

Postal code

4

1..1

 

 

Post office

4

1..1

 

 

Country

4

1..1

ISO 31661 ID used.

 

Address specifier

4

0..1

 

 

Language

4

1..1

  • fi

  • sv

 

Coordinates

3

0..1

WGS84 standard is used.

 

Latitude

4

1..1

 

 

Longitude

4

1..1

 

 

Accounting point characteristics

3

0..1

Mandatory if the status of the accounting point is not under construction or removed from use.

 

Remotely readable

4

1..1

Yes/No

 

Metering method

4

1..1

  • Continuous metering

  • Reading metering

  • Unmetered

 

Metering time step

4

1..1

 

 

User group

4

0..1

Classification specified by Statistics Finland is used based on the purpose of electricity consumption.

Mandatory for a consumption accounting point.

 

Heating depending on electricity

4

0..1

Yes/No

Mandatory for a consumption accounting point.

 

Fuse size

4

0..1

Format used:

<number of cables>x<number of phases>x<amperes>

The number of cables is excluded if only one cable is in use.

For example, 3x25, 2x3x25

 

Electric power

4

0..1

Always given in kilowatts.

 

Annual consumption estimates

4

0..2

 

 

Time division

5

1..1

Estimated annual consumption 1

Estimated annual consumption 2

 

Estimated annual consumption

5

1..1

 

 

Controlled load

3

0..n

 

 

Controlled load identification

4

1..1

 

 

Controlled load name

4

0..1

 

 

Description

4

0..1

 

 

Timings

4

0..1

 

 

Control limits

4

0..1

 

 

Maximum power

4

0..1

 

 

Maximum power unit

4

0..1

  • W

  • kW

  • MW

  • GW

 

Storage device

3

0..n

 

 

Storage device identification

4

1..1

 

 

Storage device name

4

1..1

 

 

Storage device type

4