DH-122-1 Accounting point information update

DH-122-1 Accounting point information update

Updating accounting point information

image-20251001-103858.png
Information to be reported during an accounting point update

Message DH-122-1 is of message type E58.

Message payload includes the following information:

Information field

Level

Necessity

Field content

Note

Information field

Level

Necessity

Field content

Note

Payload

1

1..1

 

 

Start of occurrence

2

1..1

 

 

Original message identification

2

0..1

If message DH-122-1 is a response to event DH-124, the field must contain the identifier of message DH-124-2.

Field usage

Original message sender

2

0..1

If message DH-122-1 is a response to event DH-124, the field must contain the sender of message DH-124-2 .

Field usage

Description

2

0..1

Optional reason for update or rejecting an update request

 

Basic accounting point data

2

1..1

 

 

Accounting point identification

3

1..1

 

 

Accounting point status

3

1..1

  • Connected

  • Disconnected

  • Under construction

 

Accounting point type

3

1..1

  • Consumption

  • Production

Information cannot be updated with the event.

Accounting point sub-type

3

1..1

  • Normal

  • Building accounting point

  • Production unit’s own consumption

  • Virtual

Accounting sub-type cannot be changed to/from ‘Virtual’.

Remotely connectable

3

1..1

Yes/No

 

Time division

3

1..1

  • One rate metering

  • Two rate metering night/day

  • Two rate metering winter day/other

 

Meter number

3

0..1

Active metering meter number

Meter number is mandatory if accounting status is not ‘Under construction’ or ‘Removed from use’ and metering method is not ‘Unmetered’.

Area information

3

1..1

 

Information cannot be updated with the event.

Metering grid area identification

4

1..1

EIC code is used.

 

Accounting point addresses

3

1..8

 

If apartment information is reported, stairwell identification is mandatory.

Address type

4

1..1

  • Main address

  • Additional address

An accounting point must have exactly one main address.

Street name

4

1..1

 

The address of an accounting point must always include the street name. If the accounting point has no official street address, the name of the nearest street is marked as the street name and the location of the accounting point is specified in the address specifier field.

Building number

4

0..1

 

 

Stairwell identification

4

0..1

 

 

Apartment

4

0..1

 

 

Postal code

4

1..1

 

The postal code and post office must match. This check is only performed for addresses located in Finland.

Post office

4

1..1

 

Country

4

1..1

ISO 31661 ID used.

 

Address specifier

4

0..1

 

 

Language

4

1..1

  • fi

  • sv

 

Coordinates

3

0..1

WGS84 standard is used.

 

Latitude

4

1..1

 

 

Longitude

4

1..1

 

 

Accounting point characteristics

3

0..1

Mandatory if the status of the accounting point is not under construction or removed from use.

 

Remotely readable

4

1..1

Yes/No

 

Metering method

4

1..1

  • Continuous metering

  • Reading metering

  • Unmetered

 

Metering time step

4

1..1

 

 

User group

4

0..1

Classification specified by Statistics Finland is used based on the purpose of electricity consumption.

Mandatory for a consumption accounting point.

 

Heating depending on electricity

4

0..1

Yes/No

Mandatory for a consumption accounting point.

 

Fuse size

4

0..1

Format used:

<number of cables>x<number of phases>x<amperes>

The number of cables is excluded if only one cable is in use.

For example, 3x25, 2x3x25

Either fuse size or electric power must be given, if accounting point is not in status ‘Under construction’ or ‘Removed from use’. If both are given, Datahub will not compare them and electric power will be used in metering data validation.

It is recommended that fuse data is recorded in messages as follows: without dashes, in lower case (x) and without ampere symbols (A, a), e.g., 3x25. If the location has several connection cables, this is entered as, e.g., 2x3x63. The 1x3x63 notation must not be used.

Electric power

4

0..1

Always given in kilowatts

Annual consumption estimates

4

0..2

 

Always given in kilowatt-hours.

Mandatory for a consumption accounting point, which is not in status ‘Under construction’.

Estimated annual consumption 2 can only be reported if also estimated annual consumption 1 has been reported.

Time division

5

1..1

Estimated annual consumption 1

Estimated annual consumption 2

 

Estimated annual consumption

5

1..1

 

 

Controlled load

3

0..n

 

The device identification – accounting point identification combination must be unique in Datahub.

Controlled load can only be reported for an accounting point with sub-type other than ‘Virtual’.

Controlled load identification

4

1..1

 

 

Controlled load name

4

0..1

 

 

Description

4

0..1

 

 

Timings

4

0..1

 

 

Control limits

4

0..1

 

 

Maximum power

4

0..1

 

 

Maximum power unit

4

0..1

  • W

  • kW

  • MW

  • GW

 

Storage device

3

0..n

 

The device identification – accounting point identification combination must be unique in Datahub.

Controlled load can only be reported for an accounting point with sub-type other than ‘Virtual’.

Identification

4

1..1

 

 

Name

4

1..1

 

 

Type

4

1..1

 

 

Capacity

4

0..1

 

 

Capacity unit

4

0..1

  • Wh

  • kWh

  • MWh

  • GWh

 

Maximum power

4

0..1

 

 

Maximum power unit