DH-124-1 Request for accounting point information update

DH-124-1 Request for accounting point information update

image-20251006-101124.png
Accounting point data for which a supplier or third party can report changes to the DSO

Message DH-124-1 is of message type E58.

Message payload includes the following information:

Information field

Level

Necessity

Field content

Note

Information field

Level

Necessity

Field content

Note

Payload

1

1..1

 

 

Start of occurrence

2

1..1

 

 

Description

2

0..1

 

 

Basic accounting point data

2

1..1

 

 

Accounting point identification

3

1..1

 

 

Area information

3

1..1

 

 

Metering grid area identification

4

1..1

 

 

Accounting point address

3

0..8

 

An update request should not be used to request removal of addresses or devices from the accounting point information.

Address type

4

1..1

  • Main address

  • Additional address

An accounting point must have exactly one main address.

Street name

4

0..1

 

 

Building number

4

0..1

 

 

Stairwell identification

4

0..1

 

 

Apartment

4

0..1

 

 

Postal code

4

0..1

 

The postal code and post office must match. This check is only performed for addresses located in Finland.

Post office

4

0..1

 

Country

4

0..1

ISO 31661 ID used.

 

Address specifier

4

0..1

 

 

Language

4

0..1

  • fi

  • sv

 

Accounting point characteristics

3

0..1

 

 

User group

4

0..1

Classification specified by Statistics Finland is used based on the purpose of electricity consumption.

 

Tax category

4

0..1

 

The tax category is agreement level data and not a characteristic of the accounting point. The tax category is included in the accounting point update request so that the supplier may request an update of the tax category.

Annual consumption estimates

4

0..2

 

Always given in kilowatt-hours.

Estimated annual consumption 2 can only be reported if estimated annual consumption 1 has also been reported.

If an annual consumption estimate is provided, it must not be the same as the one valid at the metering point on the effective date.

Time division

5

1..1

Estimated annual consumption 1

Estimated annual consumption 2

 

Estimated annual consumption

5

1..1

 

 

Controlled load

3

0..n

 

The device identification – accounting point identification combination must be unique in Datahub.

Controlled load can only be reported for an accounting point with sub-type other than ‘Virtual’.

Controlled load identification

4

1..1

 

 

Controlled load name

4

0..1

 

 

Description

4

0..1

 

 

Timings

4

0..1

 

 

Control limits

4

0..1

 

 

Maximum power

4

0..1

 

 

Maximum power unit

4

0..1

  • W

  • kW

  • MW

  • GW

 

Storage device

3

0..n

 

The device identification – accounting point identification combination must be unique in Datahub.

Controlled load can only be reported for an accounting point with sub-type other than ‘Virtual’.

Storage device identification

4

1..1

 

 

Storage device name

4

1..1

 

 

Storage device type

4

1..1

 

 

Capacity

4

0..1

 

 

Capacity unit

4

0..1

  • Wh

  • kWh

  • MWh

  • GWh

 

Maximum power

4

0..1

 

 

Maximum power unit

4

0..1

  • W

  • kW

  • MW

  • GW

 

Production device

3

0..n

 

An update request should not be used to request removal of addresses or devices from the accounting point information.

The device identification – accounting point identification combination must be unique in Datahub.

Controlled load can only be reported for an accounting point with sub-type other than ‘Virtual’.

Maximum power and maximum power unit are mandatory for a production device.

Production device identification

4

1..1

 

 

Production device name

4

1..1

 

 

Production type

4

1..1

 

 

Maximum power

4

0..1

 

Maximum power is mandatory for a production device.

Maximum power unit

4

0..1

 

Maximum power unit is mandatory for a production device.