DH-121 Notification of accounting point creation
Message DH-121 is of message type E58.
Message payload includes the following information:
Information field | Level | Necessity | Field content | Note |
|---|---|---|---|---|
Payload | 1 | 1..1 |
|
|
Start of occurrence | 2 | 1..1 |
|
|
Basic accounting point data | 2 | 1..1 |
|
|
Accounting point identification | 3 | 1..1 |
|
|
Accounting point status | 3 | 1..1 |
|
|
Accounting point type | 3 | 1..1 |
|
|
Accounting point sub-type | 3 | 1..1 |
| Accounting point sub-type ‘Virtual’ is only allowed for a production accounting point. |
Remotely connectable | 3 | 1..1 | Yes/No |
|
Time division | 3 | 1..1 |
|
|
Meter number | 3 | 0..1 | Active metering meter number | Meter number is mandatory if accounting status is not ‘Under construction’ and metering method is not ‘Unmetered’. |
Area information | 3 | 1..1 |
|
|
Metering grid area identification | 4 | 1..1 | EIC code is used. |
|
Accounting point addresses | 3 | 1..8 |
| If apartment information is reported, stairwell identification is mandatory. |
Address type | 4 | 1..1 |
| An accounting point must have exactly one main address. |
Street name | 4 | 1..1 |
| The address of an accounting point must always include the street name. If the accounting point has no official street address, the name of the nearest street is marked as the street name and the location of the accounting point is specified in the c/o field. |
Building number | 4 | 0..1 |
|
|
Stairwell identification | 4 | 0..1 |
|
|
Apartment | 4 | 0..1 |
|
|
Postal code | 4 | 1..1 |
| The post office and postal code must match. The check is performed only for addresses located in Finland. |
Post office | 4 | 1..1 |
| The post office and postal code must match. The check is performed only for addresses located in Finland. |
Country | 4 | 1..1 | ISO 31661 ID used. |
|
Address specifier | 4 | 0..1 |
|
|
Language | 4 | 1..1 |
|
|
Coordinates | 3 | 0..1 | WGS84 standard is used. |
|
Latitude | 4 | 1..1 |
|
|
Longitude | 4 | 1..1 |
|
|
Accounting point characteristics | 3 | 0..1 |
| Mandatory if the status of the accounting point is not under construction. |
Remotely readable | 4 | 1..1 | Yes/No |
|
Metering method | 4 | 1..1 |
|
|
Metering time step | 4 | 1..1 |
|
|
User group | 4 | 0..1 | Classification specified by Statistics Finland is used based on the purpose of electricity consumption. Mandatory for a consumption accounting point. |
|
Heating depending on electricity | 4 | 0..1 | Yes/No Mandatory for a consumption accounting point. |
|
Fuse size | 4 | 0..1 | Format used: <number of cables>x<number of phases>x<amperes> The number of cables is excluded if only one cable is in use. For example, 3x25, 2x3x25 | Either fuse size or electric power must be given if accounting point is not in status ‘Under construction’. If both are given, Datahub will not compare them and electric power will be used in metering data validation. It is recommended that fuse data is recorded in messages as follows: without dashes, in lower case (x) and without ampere symbols (A, a), e.g., 3x25. If the location has several connection cables, this is entered, e.g., as 2x3x63. The 1x3x63 notation must not be used. |
Electric power | 4 | 0..1 | Always given in kilowatts. | |
Annual consumption estimates | 4 | 0..2 |
| Always given in kilowatt-hours. Mandatory for a consumption accounting point, which is not in status ‘Under construction’. Estimated annual consumption 2 can only be reported if estimated annual consumption 1 has also been reported. |
Time division | 5 | 1..1 | Estimated annual consumption 1 Estimated annual consumption 2 |
|
Estimated annual consumption | 5 | 1..1 |
|
|
Controlled load | 3 | 0..n |
| The device identification – accounting point identification combination must be unique in Datahub. Controlled load can only be reported for an accounting point with sub-type other than ‘Virtual’. |
Controlled load identification | 4 | 1..1 |
|
|
Controlled load name | 4 | 0..1 |
|
|
Description | 4 | 0..1 |
|
|
Timings | 4 | 0..1 |
|
|
Control limits | 4 | 0..1 |
|
|
Maximum power | 4 | 0..1 |
|
|
Maximum power unit | 4 | 0..1 |
|
|
Storage device | 3 | 0..n |
| The device identification – accounting point identification combination must be unique in Datahub. Controlled load can only be reported for an accounting point with sub-type other than ‘Virtual’. |
Storage device identification | 4 | 1..1 |
|
|
Storage device name | 4 | 1..1 |
|
|
Storage device type | 4 | 1..1 |
|
|
Capacity | 4 | 0..1 |
|
|
Capacity unit | 4 | 0..1 |
|
|
Maximum power | 4 | 0..1 |
|
|
Maximum power unit | 4 | 0..1 |
|
|
Production device | 3 | 0..n |
| The device identification – accounting point identification combination must be unique in Datahub. Controlled load can only be reported for an accounting point with sub-type other than ‘Virtual’. |
Production device identification | 4 | 1..1 |
|
|
Production device name | 4 | 1..1 |
|
|
Production type | 4 | 1..1 |